DryCoolingTower¶
Overview¶
Class
A CoolingTower that is an indirect contact heat exchanger where, by full utilization of dry surface coil sections, no direct contact (and no evaporation) occurs between air and water; hence the water is cooled totally by sensible heat transfer (from http://data.15926.org/rdl/RDS14072386).
Supertypes
Attributes (data)
| Name | Multiplicity | Type | 
|---|---|---|
| 0..1 | ||
| 0..1 | 
Attributes (composition)
| Name | Multiplicity | Type | 
|---|---|---|
| 0..1 | 
Implementation in Proteus Schema
The class is implemented as a Proteus XML element with RDL reference.
Tag: <Equipment>
RDL reference: DRY COOLING TOWER
ComponentClass: DryCoolingTower
ComponentClassURI: http://data.posccaesar.org/rdl/RDS14072386
Example
Implementation in Proteus Schema
<Equipment
    ID="dryCoolingTower1"
    ComponentClass="DryCoolingTower"
    ComponentClassURI="http://data.posccaesar.org/rdl/RDS14072386" ...>
  ...
</Equipment>
CoolingTowerRotor¶
Attribute (composition)
The cooling tower rotor of the DryCoolingTower.
Implementation in Proteus Schema
The attribute is implemented using the XML hierarchy of the Proteus file: The  element for the attribute value (a CoolingTowerRotor) is a child of the <Equipment> element for the attribute owner (a DryCoolingTower).
Example
Implementation in Proteus Schema
<Equipment
    ID="dryCoolingTower1"
    ComponentClass="DryCoolingTower"
    ComponentClassURI="http://data.posccaesar.org/rdl/RDS14072386" ...>
  ...
  <Equipment
      ID="coolingTowerRotor1"
      ComponentClass="CoolingTowerRotor"
      ComponentClassURI="http://sandbox.dexpi.org/rdl/CoolingTowerRotor" ...>
    ...
  <Equipment />
  ...
<Equipment />
DesignRotationalSpeed¶
Attribute (data)
The rotational speed for which the DryCoolingTower is designed.
Multiplicity: 0..1
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for physical quantities.
RDL reference: DESIGN ROTATIONAL SPEED
Name: DesignRotationalSpeed
AttributeURI: http://sandbox.dexpi.org/rdl/DesignRotationalSpeed
Example
The instance dryCoolingTower1 represents a DryCoolingTower with a DesignRotationalSpeed of 180.0 min-1.
Implementation in Proteus Schema
<Equipment
    ID="dryCoolingTower1"
    ComponentClass="DryCoolingTower"
    ComponentClassURI="http://data.posccaesar.org/rdl/RDS14072386" ...>
  ...
  <GenericAttributes Set="DexpiAttributes" ...>
    <GenericAttribute
      Name="DesignRotationalSpeed"
      AttributeURI="http://sandbox.dexpi.org/rdl/DesignRotationalSpeed"
      Format="double"
      Value="180.0"
      Units="ReciprocalMinute"
      UnitsURI="http://data.posccaesar.org/rdl/RDS4316851589" />
    ...
  </GenericAttributes>
  ...
</Equipment>
DesignShaftPower¶
Attribute (data)
The shaft power for which the DryCoolingTower is designed.
Multiplicity: 0..1
Type: NullablePower
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for physical quantities.
RDL reference: DESIGN SHAFT POWER
Name: DesignShaftPower
AttributeURI: http://sandbox.dexpi.org/rdl/DesignShaftPower
Example
The instance dryCoolingTower1 represents a DryCoolingTower with a DesignShaftPower of 400.0 kW.
Implementation in Proteus Schema
<Equipment
    ID="dryCoolingTower1"
    ComponentClass="DryCoolingTower"
    ComponentClassURI="http://data.posccaesar.org/rdl/RDS14072386" ...>
  ...
  <GenericAttributes Set="DexpiAttributes" ...>
    <GenericAttribute
      Name="DesignShaftPower"
      AttributeURI="http://sandbox.dexpi.org/rdl/DesignShaftPower"
      Format="double"
      Value="400.0"
      Units="Kilowatt"
      UnitsURI="http://data.posccaesar.org/rdl/RDS1330919" />
    ...
  </GenericAttributes>
  ...
</Equipment>